Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

HOSPITECHMUMBAI 597c48957bfbbd052c2bcee5 Products https://www.reubenshospitech.com

Manufacturing test

Compact and user friendly HospiSorb is used for absorption of carbon dioxide in circle breathing application with low flows. Compatible with Hospitech range or any existing system.- Ergonomically designed & simple to use- No need for extraneous ‘T’ adaptors- Single chamber canisters single level action for canister exchange- Bypass feature to allow canister removal during operation without loss of pressure (circle ON/ OFF switch as per clause 7.2 of ISO 8835-2: 1999 (E))- Tight system with O ring seals- Satisfies leakage test - as per clause 5.1 of ISO 8835 -2: 1999 (E)- Easy cleaning - fully autoclavable (optional)- APL valve provided - In built provision to mount oxygen sensor- Bag ventilator selector switch Bi-stable as per clause 4.2 of ISO 8835-2:1999 (E)- For pediatric use single canister can be used.- Conventional diaphragm of Mica is replaced with a material that withstand autoclaving & movement of diaphragm is easily visible, minimizes resistance & ensure consistent performance- HospiSorb has a bypass feature allowing canister removal during operation without loss of circuit pressure as per clause 7.3 of ISO 8835 – 2: 1999 (E). Exchange of canister is simple via one single lever action.- Pressure manometer, -10 to 100 cm is provided as standard. Oxygen cell for sensing oxygen is accommodated directly by the absorber reducing the risk of leakage and ensuring a tidier system.
HospiSorb Breathing System
VIEW DETAILS
 Parameter: Height, Selectatec Compatable: 205 mm, Draeger plug in: 205 mm, Cage mount: 205- Parameter: Depth, Selectatec Compatable: 205 mm, Draeger plug in: 190mm, Cage mount: 210- Parameter: Width, Selectatec Compatable: 123 mm, Draeger plug in: 107 mm, Cage mount: 137Parameter: Depth, Selectatec Compatable: 6.2 kg, Draeger plug in: 6.2 kg, Cage mount: 6.2 kgACCURACY OF TRANSMITTING CONCENTRATION- Test the concentration at the exit with the recommended setup on the Ventilator: Flow: Respiratory frequency: 15 times/ minute; respiratory rate.- Accuracy of all kinds of transmission modes of the anesthesia vaporizer without actual back pressure.1) When the transmission control mode of the anesthesia gas is set at “0” position, transmitting concentration shall not exceed 0.05% (V/V).2) When the transmitting concentration is set at any other scale except “0” position, the difference between the actual transmitting concentration and the specified value shall not exceed +30% or -20% of the concentration setup value, or shall not deviate +7.5% or -5% of the maximum scale at most, and the maximum of the two shall prevail.LIQUID CAPACITY- To fully change a vaporizer with dry wicks: 300ml;- Capacity BETWEEN THE MAXIMUM AND MINIMUM SCALE: 250ml;- Retained by wick system: 40ml.FLOW RESISTANCE- 10~15 cmH2O with vaporizer setting ON +0% at 5 LPM of O2 at 20 ± 3°C.FLOW SCOPE- 0.2~15L/ min; 0.2 ~ 10L/ min (Concentration higher than 5%) REQUIREMENT ON GAS- Clean, a mixture of purely medical oxygen, air, oxygen and nitrous oxide;- Oxygen and air: Dew point <5°C- N2O: the content of water no more than 2 mg/LANGLE OF INCLINATION- Not exceeding 10°CONCENTRATION SET UP SCORE- Isoflurane, Halothane Concentration setup scope of the anesthetic vaporizer:0 ~ 5%- Sevoflurane, Enflurane Concentration setup scope of the anesthetic vaporizer:0 ~ 8%
VAP-1 Anaesthesia Vaporizer
VIEW DETAILS
SpecificationsDisplay- Display size: 15.6” Touch screen- Display type: Active matrix color TFT LCD- Resolution SVGA 1366 x 768Electrical interface- Nurse call, USB, NET, RS232, VGAInterface Type- Main patient outlet: ISO 22M/ 15F- Oxygen inlet: DISS or NIST malePhysical Dimensions- Weight < 45.3 kg- Dimensions (WxHxD): Approx: 600x402x415mmControl- Fully electronic control- Ventilation type: Blower drive- Ventilation modes:Spn-CPAP, PC-CMV, PC-ACV, PC-SIMV, PC-DUAL PAP, PC-AMV, PC-APRV, PC-MMV, VC-CMV, VC-ACV, VC-SIMV- Special functions:Manual breath, O2 therapy, standby, screen-lock, inspiratory hold, expiratory hold, sigh, ATC, PCVR, PPS, Compliance, p 0.1, calibrate, nebulizer, O2 suction.- Patient types: Adult/ Pediatric/ Neonate- Patient height: AdjustableMontoring- Real-time waveforms: PAW, Flow, Volume, EtCO2, SPO2- Optional: CO2, SPO2 (related parameters)- Loops: P-V, V-Flow, Flow-P- Trends: 1s, 5s, 1min, 10min, 30min, 60min- Tidal volume: 10 to 2000Ml- PEEP/ CPAP: 0 to 30 cmH2O- Oxygen: 21 to 100%- I:E ratio: 1:10 to 4:1- Inspiratory time (TI): 0.2 to 5s- Flow trigger: 0.2 to 15 l/min- Pressure trigger: -0.5 to -20cmH2O- Pressure control: 5 to 90 cmH2O, added to PEEP/CPAP- Pressure support: 0 to 90cmH2O, added to PEEP/CPAP- Pressure ramp: 0 to 2s- Expiratory trigger sensitivity (ETS): OFF, 5 TO 90% of inspiratory peak flow-Peak flow spontaneous: > 210 L/minElectrical and gas supplies- Input voltage: 100 to 120 V ~ ± 10%, 50/60 Hz AC or 24 VDC ± 10%- Power consumption: 50W typical- Protection class: Class I- Backup battery: 4 hours typical with one internal battery, hot swappable- Oxygen supply: 280 to 600 kPa (41 to 87 psi), 120L/min- Low pressure: oxygen ≤ 15L/min, max. 600 hPa for low pressureAlarms- Operation-adjustable:Low/high minute volume, low/high pressure, low/high tidal volume, low/high rate, apnea time, low/high oxygen- Optional: low/high CO2, low/high SPO2- Special alarms:Oxygen concentration, disconnection, loss of PEEP, exhalation obstruction, flow sensor, power supply batteries, gas supply- Sound volume adjustable: 1 to 9- Event log: Storage and display of up to 1000 events with date and time setup
RH VENT ICU Ventilator
VIEW DETAILS
SpecificationsDisplay- 15ˮ color TFT screen- Resolution: 1360 x 768dpi- Number of traces: 9 waveformsIndicator- Power indicator light- Battery indicator lightBattery - 8800mAh Rechargeable Li-ion battery- 4 hours for continuous workingNetworking- Connected to central monitoring systemI/O- LAN 1 standard RJ45 Port- WLAN IEEE802. 11b/g/n- USB 1 USB connector- Nursing call connector- VGA Output connectorECG- Lead Type: 3/5 - lead- ECG waveform: up to 12 channels- Gain selection: x0.125, x0.25, x0.5; x1; x2; auto- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s- Filter: Diagnostic mode: 0.05 - 120Hz             Monitoring mode: 0.5 - 40Hz             Surgery mode: 1 - 25Hz- Notch: 50Hz, 60Hz- Heart Rate Range:             Adult: 15 - 300bpm;             Pediatric/ Neonate: 15 - 350bpm;- Accuracy: ± 1bpm or  ± 1%, whichever is greater- Resolution:  ± 1bpmRespiration- Method: Trans-thoracic impedance- Operation modes: Auto- Measurement range:            Adult: 0 ~ 120 rpm;            Neonate/ Pediatric: 0 ~ 150 rpm- Apnea alarm delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s- Bandwidth: 0.3 to 2Hz (-3dB)- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/sSpO2- Measurement range: 0 ~ 100%- Resolution: 1%- Accuracy: ± 2% (70-100% Adult/ Pediatric);                   ± 3% (70-100% Neonate);                   0 - 69% unspecified- Refreshing rate: 1s- Sweep Speed: 12.5mm/s, 25mm/sPulse Rate- Range: 25 ~ 250bpm- Resolution: 1bpm- Accuracy: ± 3bpm non-motion                   ± 5bpm motion- Refreshing rate: 1sNIBP- Method: Automatic oscillometric- Operation modes: Manual/ Auto/ Continue- Measurement unit: mmHg/ kPa selectable- Measurement type: Systolic, Diastolic, Mean- Measurement range:- Range of systolic pressure:         Adult Mode  40 - 270 mmHg        Pediatric Mode  40 - 200 mmHg        Neonatal Mode  40 - 135 mmHg- Range of diastolic pressure:        Adult Mode  10 - 210 mmHg        Pediatric Mode  10 - 150 mmHg        Neonatal Mode  10 - 100 mmHg- Range of mean pressure:        Adult Mode  20 - 230 mmHg        Pediatric Mode  20 - 165 mmHg        Neonatal Mode  20 - 110 mmHg- Accuracy: Max mean error:  ± 5 mmHg        Max standard deviation: 8 mmHg- Over-pressure protection: Double safety protection- Resolution: 1mmHgTemperature- Accuracy: ± 0.1°C or ± 0.2°F (without probe)- Measurement range: 0~50°C (0 to 122°F)- Channel: Two-channel- Resolution: 0.1°C- Parameter: T1, T2 and TDIBP (OPTION)- Channel: 2-ch, 4-ch- Range: -50mmHg ~ 400mmHg- Resolution: 1mmHg- Sensitivity: 5uV/mmHg/V- Impedance range: 300 to 3000ΩC.O. (OPTION)- Method: Thermo dilution- Range: C.O.: 0.1 to 20L/min- T1: 0 to 27°C- Accuracy: C.o.: 5% or ± 0.1L/min, whichever is greater- TB, T1: ± 0.1°C (without sensor)Masimo ISATM Sidestream CO2 (OPTION)- Warm-up time: Full accuracy within 10 seconds- Sampling flow rate: 50mL/min (+/-10mL/min)- Accuracy: ± (0.2% + 2% of the reading)- Measurement Range: 0-15%- Rise time: 200ms, typical at 50mL/min flow rate- Total response time: within 3 seconds (with 2m Nomo line sampling line)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathMasimo IRMA TM Mainstream CO2 (OPTION)- Measurement Range: 0-15%- Warm-up time: Full accuracy within 10 seconds- Accuracy: ± (0.2% + 2% of the reading)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathOperation Environment- PowerAC 100-250V, 50/60Hz.- Temperature 0-40°C- Humidity15-85%- Patient RangeAdult, Pediatric, Neonate
iA-15 Multipara Patient Monitor
VIEW DETAILS
SpecificationsDisplay- 12.1ˮ color TFT screen- Resolution: 800 x 600dpiIndicator- Power indicator light- Battery indicator lightBattery- 4400mAh Rechargeable Li-ion batteryNetworking- Connected to central monitoring systemI/O- LAN 1 standard RJ45 Port- USB 1 USB connector- SD 1 SD card connector- Nursing call connectorECG- Lead Type: 3/5 – lead- Gain selection: x0.125, x0.25, x0.5; x1; x2; auto- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s- Filter: Diagnostic mode: 0.05 - 120Hz            Monitoring mode: 0.5 - 40Hz            Surgery mode: 1 - 25Hz- Notch: 50Hz, 60Hz- Heart Rate Range:            Adult: 15 - 300bpm;            Pediatric/ Neonate: 15 - 350bpm;- Accuracy: ± 1bpm or ± 1%, whichever is greater- Resolution:  ± 1bpmRespiration- Method: Trans-thoracic impedance- Operation modes: Auto- Measurement range:            Adult: 0 ~ 120 rpm         Neonate/ Pediatric: 0 ~ 150 rpm         Apnea alarm delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s         Bandwidth: 0.3 to 2Hz (-3dB)         Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/sSpO2- Measurement range: 0 ~ 100%- Resolution: 1%- Accuracy: ± 2% (70-100% Adult/ Pediatric);                   ± 3% (70-100% Neonate);                   0 - 69% unspecified- Refreshing rate: 1s- Sweep Speed: 12.5mm/s, 25mm/sPulse Rate- Range: 25 ~ 250bpm- Resolution: 1bpm- Accuracy: ± 3bpm non-motion                   ± 5bpm motion- Refreshing rate: 1sNIBP- Method: Automatic oscillometric- Operation modes: Manual/ Auto/ Continue- Measurement unit: mmHg/ kPa selectable- Measurement type: Systolic, Diastolic, Mean- Measurement range:- Range of systolic pressure:        Adult Mode 40 - 270 mmHg        Pediatric Mode 40 - 200 mmHg        Neonatal Mode 40 - 135 mmHg- Range of diastolic pressure:        Adult Mode 10 - 210 mmHg        Pediatric Mode 10 - 150 mmHg        Neonatal Mode 10 - 100 mmHg- Range of mean pressure:        Adult Mode  20 - 230 mmHg        Pediatric Mode  20 - 165 mmHg        Neonatal Mode  20 - 110 mmHg- Accuracy: Max mean error:  ± 5 mmHg        Max standard deviation: 8 mmHg- Over-pressure protection: Double safety protection- Resolution: 1mmHgTemperature- Accuracy: ± 0.1°C or ± 0.2°F (without probe)- Measurement range: 0~50°C (41 to 122°F)- Channel: Two-channel- Resolution: 0.1°C- Parameter: T1, T2 and TDIBP (OPTION)- Channel: 2-ch, 4-ch- Range: -50mmHg ~ 400mmHg- Resolution: 1mmHg- Accuracy: ±2% or ±1mmHg, whichever is greater- Sensitivity: 5uV/mmHg/V- Impedance range: 300 to 3000ΩC.O. (OPTION)- Method: Thermo dilution- Range: C.O.: 0.1 to 20L/min       TB: 23 TO 43°C       T1: 0 to 27°C- Accuracy: C.o.: 5% or ± 0.1L/min, whichever is greater- TB, T1: ± 0.1°C (without sensor)Masimo ISATM Sidestream CO2 (OPTION)- Warm-up time: Full accuracy within 10 seconds- Sampling flow rate: 50mL/min (+/-10mL/min)- Accuracy: ± (0.2% + 2% of the reading)- Measurement Range: 0-15%- Rise time: 200ms, typical at 50mL/min flow rate- Total response time: within 3 seconds (with 2m Nomo line sampling line)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathMasimo IRMA TM Mainstream CO2 (OPTION)- Measurement Range: 0-15%- Warm-up time: Full accuracy within 10 seconds- Accuracy: ± (0.2% + 2% of the reading)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathOperation Environment- PowerAC 100-250V, 50/60Hz.- Temperature 0-40°C- Humidity15-85%- Patient RangeAdult, Pediatric, Neonate
iA-12 Multipara Patient Monitor
VIEW DETAILS
SpecificationsDisplay- 8ˮ color TFT screen- Resolution: 800 x 600dpiIndicator- Power indicator light- Battery indicator lightBattery- 4400mAh Rechargeable Li-ion battery- 4hours for continuous workingNetworking- Connected to central monitoring systemI/O- LAN 1 standard RJ45 Port- USB 1 USB connector- SD 1 SD card connector- Nursing call connectorECG- Lead Type: 3/5 – lead- Gain selection: x0.125, x0.25, x0.5; x1; x2; auto- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s- Filter: Diagnostic mode: 0.05 - 120Hz            Monitoring mode: 0.5 - 40Hz            Surgery mode: 1 - 25Hz- Notch: 50Hz, 60Hz- Heart Rate Range:            Adult: 15 - 300bpm;            Pediatric/ Neonate: 15 - 350bpm;- Accuracy: ± 1bpm or ± 1%, whichever is greater- Resolution:  ± 1bpmRespiration- Method: Trans-thoracic impedance- Operation modes: Auto- Measurement range:         Adult: 0 ~ 120 rpm         Neonate/ Pediatric: 0 ~ 150 rpm         Apnea alarm delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s         Bandwidth: 0.3 to 2Hz (-3dB)         Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/sSpO2- Measurement range: 0 ~ 100%- Resolution: 1%- Accuracy: ± 2% (70-100% Adult/ Pediatric);                   ± 3% (70-100% Neonate);                   0 - 69% unspecified- Refreshing rate: 1s- Sweep Speed: 12.5mm/s, 25mm/sPulse Rate- Range: 25 ~ 250bpm- Resolution: 1bpm- Accuracy: ± 3bpm non-motion                   ± 5bpm motion- Refreshing rate: 1sNIBP- Method: Automatic oscillometric- Operation modes: Manual/ Auto/ Continue- Measurement unit: mmHg/ kPa selectable- Measurement type: Systolic, Diastolic, Mean- Measurement range:- Range of systolic pressure:        Adult Mode 40 - 270 mmHg        Pediatric Mode 40 - 200 mmHg        Neonatal Mode 40 - 135 mmHg- Range of diastolic pressure:        Adult Mode 10 - 210 mmHg        Pediatric Mode 10 - 150 mmHg        Neonatal Mode 10 - 100 mmHg- Range of mean pressure:        Adult Mode  20 - 230 mmHg        Pediatric Mode  20 - 165 mmHg        Neonatal Mode  20 - 110 mmHg- Accuracy: Max mean error:  ± 5 mmHg        Max standard deviation: 8 mmHg- Over-pressure protection: Double safety protection- Resolution: 1mmHgTemperature- Accuracy: ± 0.1°C or ± 0.2°F (without probe)- Measurement range: 0~50°C (0 to 122°F)- Channel: Two-channel- Resolution: 0.1°C- Parameter: T1, T2 and TDMasimo ISATM Sidestream CO2 (OPTION)- Warm-up time: Full accuracy within 10 seconds- Sampling flow rate: 50mL/min (+/-10mL/min)- Accuracy: ± (0.2% + 2% of the reading)- Measurement Range: 0-15%- Rise time: 200ms, typical at 50mL/min flow rate- Total response time: within 3 seconds (with 2m Nomo line sampling line)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathMasimo IRMA TM Mainstream CO2 (OPTION)- Measurement Range: 0-15%- Warm-up time: Full accuracy within 10 seconds- Accuracy: ± (0.2% + 2% of the reading)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathOperation Environment- PowerAC 100-250V, 50/60Hz.- Temperature 0-40°C- Humidity15-85%- Patient RangeAdult, Pediatric, Neonate
iA-8 Multipara Patient Monitor
VIEW DETAILS
X3 is a pneumatically driven and electronically controlled anaesthesia ventilator with more accurate volume delivery, superior control, facilitate advanced ventilation modes with an easy to use interface experience   Features- 5.7
X3 Anaesthesia Ventilator
VIEW DETAILS
X5 is a pneumatically driven and electronically controlled anaesthesia ventilator with more accurate volume delivery, superior control, facilitate advanced ventilation modes with an easy to use interface experience   Features- 8
X5 Anaesthesia Ventilator
VIEW DETAILS
X6 is a pneumatically driven and electronically controlled anaesthesia ventilator with more accurate volume delivery, superior control, facilitate advanced ventilation modes with an easy to use interface experience   Features- 10.4
X6 Anaesthesia Ventilator
VIEW DETAILS
A fine product from Reubens Hospitech, has established itself as a reliable brand in innumerable operation theatre across the country. Its compact size, elegant appeal provide a long lasting payback to the valuable trust placed on the product.- Machine should be constructed with sturdy frame of corrosion proof medical grade material with durable finish- Mounted on 4 wheels, front 2 having brakes- Top shelf having weight bearing capacity of minimum 25 kgs- All gauges to be mounted in behind the middle panel- Separate cylinder pressure gauge for O2/N2O for each source of inlet- Should have provision to attach 1 pin type cylinder of each gas i.e, O2, N2O- O2 failure alarm and N2O to cut off when the pressure in any source of O2 falls below 250 kPa- Common Gas Outlet (CGO) provided- Non interchangeable gas supply inlet for O2/ N2O and Air as per standards- Blow off valve for patient safety to ensure that not more than 120 cm of water pressure is delivered to the patient at any given point of time
MINI COMPACT Anaesthesia Machine
VIEW DETAILS
Major anaesthesia machine is designed for those who desire the best in simplicity. The machine provides two yokes each for O2 and N2O gases and is suitable for uses that generally last for less than 2 hrs.
MAJOR Anaesthesia Machine
VIEW DETAILS
A fine product from Reubens Hospitech, has established itself as a reliable brand in innumerable operation theatres across the country. The high end features present in the machine along with its elegant appeal provide a long lasting payback to the valuable trust placed on the product. - Machine constructed with sturdy frame of corrosion proof medical grade material with durable finish- Mounted on 4 wheels, front 2 having brakes- Top shelf having weight bearing capacity of minimum 50 kgs- All gauges to be mounted in front panel- System has ON/OFF switch- Separate cylinder and pipeline pressure gauge for O2/ N2O/ Air - Provision to attach 2 pin type cylinder of each gas i.e, O2 and N2O  - Separate pipeline inlet for O2, N2O and Air- 5 tube cascaded rotameter for O2, N2O AND Air for delivery of low flow anesthesia- O2 failure alarm and N2O cut off when the pressure in any source of O2 fall below 205 kPa - Common Gas Outlet (CGO) provided- Non interchangeable gas supply inlet for O2, N2O and Air as per standards- ORC/ equivalent system to insure that 23% to 25% O2 is always maintained at any point of supply of gas to the patient (Anti Hypoxia guard)- Blow off valve for patient safety to ensure that not more than 120cm of water pressure is delivered to the patient at any point of time
MAJOR PLUS Anaesthesia Machine
VIEW DETAILS

Filter using tags

anaesthesia workstation, anaesthesia machineanaesthesia anaesthesia machine#anaesthesia #anaesthesiaworkstationmultipara patient monitor, patient monitor, monitomultipara patient monitor, patient monitor,monitoranesthesia breathing system,ciranaesthesia, anaesthesia ventilatoricu ventilator, ventilatoranesthesia vaporizer, vaporizer`l

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us