Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

HOSPITECHMUMBAI 597c48957bfbbd052c2bcee5 Products https://www.reubenshospitech.com
multipara patient monitor patient monitor monitor
SpecificationsDisplay- 15ˮ color TFT screen- Resolution: 1360 x 768dpi- Number of traces: 9 waveformsIndicator- Power indicator light- Battery indicator lightBattery - 8800mAh Rechargeable Li-ion battery- 4 hours for continuous workingNetworking- Connected to central monitoring systemI/O- LAN 1 standard RJ45 Port- WLAN IEEE802. 11b/g/n- USB 1 USB connector- Nursing call connector- VGA Output connectorECG- Lead Type: 3/5 - lead- ECG waveform: up to 12 channels- Gain selection: x0.125, x0.25, x0.5; x1; x2; auto- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s- Filter: Diagnostic mode: 0.05 - 120Hz             Monitoring mode: 0.5 - 40Hz             Surgery mode: 1 - 25Hz- Notch: 50Hz, 60Hz- Heart Rate Range:             Adult: 15 - 300bpm;             Pediatric/ Neonate: 15 - 350bpm;- Accuracy: ± 1bpm or  ± 1%, whichever is greater- Resolution:  ± 1bpmRespiration- Method: Trans-thoracic impedance- Operation modes: Auto- Measurement range:            Adult: 0 ~ 120 rpm;            Neonate/ Pediatric: 0 ~ 150 rpm- Apnea alarm delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s- Bandwidth: 0.3 to 2Hz (-3dB)- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/sSpO2- Measurement range: 0 ~ 100%- Resolution: 1%- Accuracy: ± 2% (70-100% Adult/ Pediatric);                   ± 3% (70-100% Neonate);                   0 - 69% unspecified- Refreshing rate: 1s- Sweep Speed: 12.5mm/s, 25mm/sPulse Rate- Range: 25 ~ 250bpm- Resolution: 1bpm- Accuracy: ± 3bpm non-motion                   ± 5bpm motion- Refreshing rate: 1sNIBP- Method: Automatic oscillometric- Operation modes: Manual/ Auto/ Continue- Measurement unit: mmHg/ kPa selectable- Measurement type: Systolic, Diastolic, Mean- Measurement range:- Range of systolic pressure:         Adult Mode  40 - 270 mmHg        Pediatric Mode  40 - 200 mmHg        Neonatal Mode  40 - 135 mmHg- Range of diastolic pressure:        Adult Mode  10 - 210 mmHg        Pediatric Mode  10 - 150 mmHg        Neonatal Mode  10 - 100 mmHg- Range of mean pressure:        Adult Mode  20 - 230 mmHg        Pediatric Mode  20 - 165 mmHg        Neonatal Mode  20 - 110 mmHg- Accuracy: Max mean error:  ± 5 mmHg        Max standard deviation: 8 mmHg- Over-pressure protection: Double safety protection- Resolution: 1mmHgTemperature- Accuracy: ± 0.1°C or ± 0.2°F (without probe)- Measurement range: 0~50°C (0 to 122°F)- Channel: Two-channel- Resolution: 0.1°C- Parameter: T1, T2 and TDIBP (OPTION)- Channel: 2-ch, 4-ch- Range: -50mmHg ~ 400mmHg- Resolution: 1mmHg- Sensitivity: 5uV/mmHg/V- Impedance range: 300 to 3000ΩC.O. (OPTION)- Method: Thermo dilution- Range: C.O.: 0.1 to 20L/min- T1: 0 to 27°C- Accuracy: C.o.: 5% or ± 0.1L/min, whichever is greater- TB, T1: ± 0.1°C (without sensor)Masimo ISATM Sidestream CO2 (OPTION)- Warm-up time: Full accuracy within 10 seconds- Sampling flow rate: 50mL/min (+/-10mL/min)- Accuracy: ± (0.2% + 2% of the reading)- Measurement Range: 0-15%- Rise time: 200ms, typical at 50mL/min flow rate- Total response time: within 3 seconds (with 2m Nomo line sampling line)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathMasimo IRMA TM Mainstream CO2 (OPTION)- Measurement Range: 0-15%- Warm-up time: Full accuracy within 10 seconds- Accuracy: ± (0.2% + 2% of the reading)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathOperation Environment- PowerAC 100-250V, 50/60Hz.- Temperature 0-40°C- Humidity15-85%- Patient RangeAdult, Pediatric, Neonate
iA-15 Multipara Patient Monitor
VIEW DETAILS
SpecificationsDisplay- 12.1ˮ color TFT screen- Resolution: 800 x 600dpiIndicator- Power indicator light- Battery indicator lightBattery- 4400mAh Rechargeable Li-ion batteryNetworking- Connected to central monitoring systemI/O- LAN 1 standard RJ45 Port- USB 1 USB connector- SD 1 SD card connector- Nursing call connectorECG- Lead Type: 3/5 – lead- Gain selection: x0.125, x0.25, x0.5; x1; x2; auto- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s- Filter: Diagnostic mode: 0.05 - 120Hz            Monitoring mode: 0.5 - 40Hz            Surgery mode: 1 - 25Hz- Notch: 50Hz, 60Hz- Heart Rate Range:            Adult: 15 - 300bpm;            Pediatric/ Neonate: 15 - 350bpm;- Accuracy: ± 1bpm or ± 1%, whichever is greater- Resolution:  ± 1bpmRespiration- Method: Trans-thoracic impedance- Operation modes: Auto- Measurement range:            Adult: 0 ~ 120 rpm         Neonate/ Pediatric: 0 ~ 150 rpm         Apnea alarm delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s         Bandwidth: 0.3 to 2Hz (-3dB)         Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/sSpO2- Measurement range: 0 ~ 100%- Resolution: 1%- Accuracy: ± 2% (70-100% Adult/ Pediatric);                   ± 3% (70-100% Neonate);                   0 - 69% unspecified- Refreshing rate: 1s- Sweep Speed: 12.5mm/s, 25mm/sPulse Rate- Range: 25 ~ 250bpm- Resolution: 1bpm- Accuracy: ± 3bpm non-motion                   ± 5bpm motion- Refreshing rate: 1sNIBP- Method: Automatic oscillometric- Operation modes: Manual/ Auto/ Continue- Measurement unit: mmHg/ kPa selectable- Measurement type: Systolic, Diastolic, Mean- Measurement range:- Range of systolic pressure:        Adult Mode 40 - 270 mmHg        Pediatric Mode 40 - 200 mmHg        Neonatal Mode 40 - 135 mmHg- Range of diastolic pressure:        Adult Mode 10 - 210 mmHg        Pediatric Mode 10 - 150 mmHg        Neonatal Mode 10 - 100 mmHg- Range of mean pressure:        Adult Mode  20 - 230 mmHg        Pediatric Mode  20 - 165 mmHg        Neonatal Mode  20 - 110 mmHg- Accuracy: Max mean error:  ± 5 mmHg        Max standard deviation: 8 mmHg- Over-pressure protection: Double safety protection- Resolution: 1mmHgTemperature- Accuracy: ± 0.1°C or ± 0.2°F (without probe)- Measurement range: 0~50°C (41 to 122°F)- Channel: Two-channel- Resolution: 0.1°C- Parameter: T1, T2 and TDIBP (OPTION)- Channel: 2-ch, 4-ch- Range: -50mmHg ~ 400mmHg- Resolution: 1mmHg- Accuracy: ±2% or ±1mmHg, whichever is greater- Sensitivity: 5uV/mmHg/V- Impedance range: 300 to 3000ΩC.O. (OPTION)- Method: Thermo dilution- Range: C.O.: 0.1 to 20L/min       TB: 23 TO 43°C       T1: 0 to 27°C- Accuracy: C.o.: 5% or ± 0.1L/min, whichever is greater- TB, T1: ± 0.1°C (without sensor)Masimo ISATM Sidestream CO2 (OPTION)- Warm-up time: Full accuracy within 10 seconds- Sampling flow rate: 50mL/min (+/-10mL/min)- Accuracy: ± (0.2% + 2% of the reading)- Measurement Range: 0-15%- Rise time: 200ms, typical at 50mL/min flow rate- Total response time: within 3 seconds (with 2m Nomo line sampling line)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathMasimo IRMA TM Mainstream CO2 (OPTION)- Measurement Range: 0-15%- Warm-up time: Full accuracy within 10 seconds- Accuracy: ± (0.2% + 2% of the reading)- AWRR Range: 0-150bpm- AWRR Accuracy: ± 1 breathOperation Environment- PowerAC 100-250V, 50/60Hz.- Temperature 0-40°C- Humidity15-85%- Patient RangeAdult, Pediatric, Neonate
iA-12 Multipara Patient Monitor
VIEW DETAILS

Filter using tags

anaesthesia workstation, anaesthesia machineanaesthesia anaesthesia machine#anaesthesia #anaesthesiaworkstationmultipara patient monitor, patient monitor, monitomultipara patient monitor, patient monitor,monitoranesthesia breathing system,ciranaesthesia, anaesthesia ventilatoricu ventilator, ventilatoranesthesia vaporizer, vaporizer`l

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us