Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

HOSPITECHMUMBAI 597c48957bfbbd052c2bcee5 Products https://www.reubenshospitech.com
anesthesia vaporizer vaporizer
 Parameter: Height, Selectatec Compatable: 205 mm, Draeger plug in: 205 mm, Cage mount: 205- Parameter: Depth, Selectatec Compatable: 205 mm, Draeger plug in: 190mm, Cage mount: 210- Parameter: Width, Selectatec Compatable: 123 mm, Draeger plug in: 107 mm, Cage mount: 137Parameter: Depth, Selectatec Compatable: 6.2 kg, Draeger plug in: 6.2 kg, Cage mount: 6.2 kgACCURACY OF TRANSMITTING CONCENTRATION- Test the concentration at the exit with the recommended setup on the Ventilator: Flow: Respiratory frequency: 15 times/ minute; respiratory rate.- Accuracy of all kinds of transmission modes of the anesthesia vaporizer without actual back pressure.1) When the transmission control mode of the anesthesia gas is set at “0” position, transmitting concentration shall not exceed 0.05% (V/V).2) When the transmitting concentration is set at any other scale except “0” position, the difference between the actual transmitting concentration and the specified value shall not exceed +30% or -20% of the concentration setup value, or shall not deviate +7.5% or -5% of the maximum scale at most, and the maximum of the two shall prevail.LIQUID CAPACITY- To fully change a vaporizer with dry wicks: 300ml;- Capacity BETWEEN THE MAXIMUM AND MINIMUM SCALE: 250ml;- Retained by wick system: 40ml.FLOW RESISTANCE- 10~15 cmH2O with vaporizer setting ON +0% at 5 LPM of O2 at 20 ± 3°C.FLOW SCOPE- 0.2~15L/ min; 0.2 ~ 10L/ min (Concentration higher than 5%) REQUIREMENT ON GAS- Clean, a mixture of purely medical oxygen, air, oxygen and nitrous oxide;- Oxygen and air: Dew point <5°C- N2O: the content of water no more than 2 mg/LANGLE OF INCLINATION- Not exceeding 10°CONCENTRATION SET UP SCORE- Isoflurane, Halothane Concentration setup scope of the anesthetic vaporizer:0 ~ 5%- Sevoflurane, Enflurane Concentration setup scope of the anesthetic vaporizer:0 ~ 8%
VAP-1 Anaesthesia Vaporizer
VIEW DETAILS

Filter using tags

anaesthesia workstation, anaesthesia machineanaesthesia anaesthesia machine#anaesthesia #anaesthesiaworkstationmultipara patient monitor, patient monitor, monitomultipara patient monitor, patient monitor,monitoranesthesia breathing system,ciranaesthesia, anaesthesia ventilatoricu ventilator, ventilatoranesthesia vaporizer, vaporizer`l

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us