iA-12 Multipara Patient Monitor Specifications Display - 12.1ˮ color TFT screen - Resolution: 800 x 600dpi Indicator - Power indicator light - Battery indicator light Battery - 4400mAh Rechargeable Li-ion battery Networking - Connected to central monitoring system I/O - LAN 1 standard RJ45 Port - USB 1 USB connector - SD 1 SD card connector - Nursing call connector ECG - Lead Type: 3/5 – lead - Gain selection: x0.125, x0.25, x0.5; x1; x2; auto - Sweep speed: 12.5mm/s, 25mm/s, 50mm/s - Filter: Diagnostic mode: 0.05 - 120Hz, Monitoring mode: 0.5 - 40Hz, Surgery mode: 1 - 25Hz - Notch: 50Hz, 60Hz - Heart Rate Range : Adult: 15 - 300bpm; Pediatric/ Neonate: 15 - 350bpm; - Accuracy: ± 1bpm or ± 1%, whichever is greater - Resolution: ± 1bpm Respiration - Method: Trans-thoracic impedance - Operation modes: Auto - Measurement range : Adult: 0 ~ 120 rpm, Neonate/ Pediatric: 0 ~ 150 rpm - Apnea alarm delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s - Bandwidth: 0.3 to 2Hz (-3dB) - Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s SpO2 - Measurement range: 0 ~ 100% - Resolution: 1% - Accuracy: ± 2% (70-100% Adult/ Pediatric); ± 3% (70-100% Neonate); - Refreshing rate: 1s - Sweep Speed: 12.5mm/s, 25mm/s Pulse Rate - Range: 25 ~ 250bpm - Resolution: 1bpm - Accuracy: ± 3bpm non-motion and ± 5bpm motion - Refreshing rate: 1s NIBP - Method: Automatic oscillometric - Operation modes: Manual/ Auto/ Continue - Measurement unit: mmHg/ kPa selectable - Measurement type: Systolic, Diastolic, Mean - Measurement range: - Range of systolic pressure: Adult Mode 40 - 270 mmHg Pediatric Mode 40 - 200 mmHg Neonatal Mode 40 - 135 mmHg - Range of diastolic pressure: Adult Mode 10 - 210 mmHg Pediatric Mode 10 - 150 mmHg Neonatal Mode 10 - 100 mmHg - Range of mean pressure: Adult Mode 20 - 230 mmHg Pediatric Mode 20 - 165 mmHg Neonatal Mode 20 - 110 mmHg - Accuracy: Max mean error: ± 5 mmHg, Max standard deviation: 8 mmHg - Over-pressure protection: Double safety protection - Resolution: 1mmHg Temperature - Accuracy: ± 0.1°C or ± 0.2°F (without probe) - Measurement range: 0~50°C (41 to 122°F) - Channel: Two-channel - Resolution: 0.1°C - Parameter: T1, T2 and TD IBP (OPTION) - Channel: 2-ch, 4-ch - Range: -50mmHg ~ 400mmHg - Resolution: 1mmHg - Accuracy: ±2% or ±1mmHg, whichever is greater - Sensitivity: 5uV/mmHg/V - Impedance range: 300 to 3000Ω C.O. (OPTION) - Method: Thermo dilution - Range: C.O.: 0.1 to 20L/min, TB: 23 TO 43°C, T1: 0 to 27°C - Accuracy: C.o.: 5% or ± 0.1L/min, whichever is greater - TB, T1: ± 0.1°C (without sensor) Masimo ISATM Sidestream CO2 (OPTION) - Warm-up time: Full accuracy within 10 seconds - Sampling flow rate: 50mL/min (+/-10mL/min) - Accuracy: ± (0.2% + 2% of the reading) - Measurement Range: 0-15% - Rise time: 200ms, typical at 50mL/min flow rate - Total response time: within 3 seconds (with 2m Nomo line sampling line) - AWRR Range: 0-150bpm - AWRR Accuracy: ± 1 breath Masimo IRMA TM Mainstream CO2 (OPTION) - Measurement Range: 0-15% - Warm-up time: Full accuracy within 10 seconds - Accuracy: ± (0.2% + 2% of the reading) - AWRR Range: 0-150bpm - AWRR Accuracy: ± 1 breath Operation Environment - Power : AC 100-250V, 50/60Hz. - Temperature : 0-40°C - Humidity : 15-85% - Patient Range : Adult, Pediatric, Neonate
Submit Your Enquiry