  • 2019-07-31T08:51:37

RH VENT ICU Ventilator Specifications Display - Display size: 15.6” Touch screen - Display type: Active matrix color TFT LCD - Resolution SVGA 1366 x 768 Electrical interface - Nurse call, USB, NET, RS232, VGA Interface Type - Main patient outlet: ISO 22M/ 15F - Oxygen inlet: DISS or NIST male Physical Dimensions - Weight < 45.3 kg - Dimensions (WxHxD): Approx: 600x402x415mm Control - Fully electronic control - Ventilation type: Blower drive - Ventilation modes : Spn-CPAP, PC-CMV, PC-ACV, PC-SIMV, PC-DUAL PAP, PC-AMV, PC-APRV, PC-MMV, VC-CMV, VC-ACV, VC-SIMV - Special functions : Manual breath, O2 therapy, standby, screen-lock, inspiratory hold, expiratory hold, sigh, ATC, PCVR, PPS, Compliance, p 0.1, calibrate, nebulizer, O2 suction. - Patient types: Adult/ Pediatric/ Neonate - Patient height: Adjustable Monitoring - Real-time waveforms: PAW, Flow, Volume, EtCO2, SPO2 - Optional: CO2, SPO2 (related parameters) - Loops: P-V, V-Flow, Flow-P - Trends: 1s, 5s, 1min, 10min, 30min, 60min - Tidal volume: 10 to 2000Ml - PEEP/ CPAP: 0 to 30 cmH2O - Oxygen: 21 to 100% - I:E ratio: 1:10 to 4:1 - Inspiratory time (TI): 0.2 to 5s - Flow trigger: 0.2 to 15 l/min - Pressure trigger: -0.5 to -20cmH2O - Pressure control: 5 to 90 cmH2O, added to PEEP/CPAP - Pressure support: 0 to 90cmH2O, added to PEEP/CPAP - Pressure ramp: 0 to 2s - Expiratory trigger sensitivity (ETS): OFF, 5 TO 90% of inspiratory peak flow -Peak flow spontaneous: > 210 L/min Electrical and gas supplies - Input voltage: 100 to 120 V ~ ± 10%, 50/60 Hz AC or 24 VDC ± 10% - Power consumption: 50W typical - Protection class: Class I - Backup battery: 4 hours typical with one internal battery, hot swappable - Oxygen supply: 280 to 600 kPa (41 to 87 psi), 120L/min - Low pressure: oxygen ≤ 15L/min, max. 600 hPa for low pressure Alarms - Operation-adjustable : Low/high minute volume, low/high pressure, low/high tidal volume, low/high rate, apnea time, low/high oxygen - Optional : low/high CO2, low/high SPO2 - Special alarms : Oxygen concentration, disconnection, loss of PEEP, exhalation obstruction, flow sensor, power supply batteries, gas supply - Sound volume adjustable : 1 to 9 - Event log : Storage and display of up to 1000 events with date and time setup

RH VENT ICU Ventilator Specifications Display - Display size: 15.6” Touch screen - Display type: Active matrix color TFT LCD - Resolution SVGA 1366 x 768 Electrical interface - Nurse call, USB, NET, RS232, VGA Interface Type - Main patient outlet: ISO 22M/ 15F - Oxygen inlet: DISS or NIST male Physical Dimensions - Weight < 45.3 kg - Dimensions (WxHxD): Approx: 600x402x415mm Control - Fully electronic control - Ventilation type: Blower drive - Ventilation modes : Spn-CPAP, PC-CMV, PC-ACV, PC-SIMV, PC-DUAL PAP, PC-AMV, PC-APRV, PC-MMV, VC-CMV, VC-ACV, VC-SIMV - Special functions : Manual breath, O2 therapy, standby, screen-lock, inspiratory hold, expiratory hold, sigh, ATC, PCVR, PPS, Compliance, p 0.1, calibrate, nebulizer, O2 suction. - Patient types: Adult/ Pediatric/ Neonate - Patient height: Adjustable Monitoring - Real-time waveforms: PAW, Flow, Volume, EtCO2, SPO2 - Optional: CO2, SPO2 (related parameters) - Loops: P-V, V-Flow, Flow-P - Trends: 1s, 5s, 1min, 10min, 30min, 60min - Tidal volume: 10 to 2000Ml - PEEP/ CPAP: 0 to 30 cmH2O - Oxygen: 21 to 100% - I:E ratio: 1:10 to 4:1 - Inspiratory time (TI): 0.2 to 5s - Flow trigger: 0.2 to 15 l/min - Pressure trigger: -0.5 to -20cmH2O - Pressure control: 5 to 90 cmH2O, added to PEEP/CPAP - Pressure support: 0 to 90cmH2O, added to PEEP/CPAP - Pressure ramp: 0 to 2s - Expiratory trigger sensitivity (ETS): OFF, 5 TO 90% of inspiratory peak flow -Peak flow spontaneous: > 210 L/min Electrical and gas supplies - Input voltage: 100 to 120 V ~ ± 10%, 50/60 Hz AC or 24 VDC ± 10% - Power consumption: 50W typical - Protection class: Class I - Backup battery: 4 hours typical with one internal battery, hot swappable - Oxygen supply: 280 to 600 kPa (41 to 87 psi), 120L/min - Low pressure: oxygen ≤ 15L/min, max. 600 hPa for low pressure Alarms - Operation-adjustable : Low/high minute volume, low/high pressure, low/high tidal volume, low/high rate, apnea time, low/high oxygen - Optional : low/high CO2, low/high SPO2 - Special alarms : Oxygen concentration, disconnection, loss of PEEP, exhalation obstruction, flow sensor, power supply batteries, gas supply - Sound volume adjustable : 1 to 9 - Event log : Storage and display of up to 1000 events with date and time setup

  • 2019-07-31T08:51:37

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us